MY HOME
285
Energy management
General concepts
The Temperature control system
must be appropriately configured so
that it can work properly and so that
each item can perform the required
function.
Configuring basically means
interacting with the unit and actuator
probes, thus defining:
For the probes and the 4 zone
control unit:
a) the zone of belonging
b) any slave probes managed
For the probes:
a) “Master or “Slave mode
(if necessary)
For the actuators:
a) the zone of belonging
b) the type of load to manage
c) the number of actuators
belonging to the same zone
For the central units:
a) the zones of the system and
their name
b) the functioning mode of the
actuators (heating, cooling, ecc.)
c) the type of load to be controlled
(solenoid valves, fan-coil, etc.)
d) the pumps in the system
e) the control mode of the pumps
(heating, cooling, etc.)
f ) the startup delay of the pumps
(if necessary)
ZONE ZA AND ZB
Address of the devices belonging
to a logical zone; as an example in
a dwelling one can talk about night
area, day area and cellar.
PROGRESSIVE ZONE NUMBER N
Numeric identification of the single
actuator inside the same zone.
ACTUATOR ADDRESS
The address of each actuator is
uniquely defined by inserting the
numeric configurators from 0 to 9 in
positions ZA and ZB. For each zone
a maximum of 9 addresses can be
defined by inserting the numeric
configurators from 1 to 9 in position
N; a maximum of 4 or 99 zones can be
defined in a system, according to the
control unit used.
Up to 99 zones can be managed in a
system; 2 configurators will thus be
needed to define the zone number.
PROBES ADDRESS
The probes also have positions ZA
and ZB to define the address of the
devices which will receive the control
(actuators). These positions have
numeric configurators which enable
the device to send the control.