MY HOME
WIRING DIAGRAMS
Energy management
CONTACT INTERFACE
CONFIGURATION
Then configure housings Z1/2 and
N1/2 depending on the requirements
and features of the burglar-alarm
system (see the burglar-alarm
technical guide).
The coupling between the interface
contact line and the temperature
control zone must be performed
using the TiThermo application.
mod1/mod2 type of ContaCt and mode
4 NC
5 Balanced
6 NC - delayed
7 NC - Balanced - delayed
radiant panel ON radiant panel OFF radiant panel
back ON automatically
WINDOW
CLOSED
WINDOW
OPENING
WINDOW
LEFT OPEN
time can be set from 5
minutes to unlimited
REACTIVATION TIME
The reactivation time can be set from
5 to 55 minutes, or on unlimited.
When the time set has elapsed the
system reactivates the temperature
control zone even if windows or
doors are still open.
Even if it goes against the concept of
energy saving this function is useful
when the windows have been left
open and the temperature set in
the room must be kept the same.
When the reactivation time is set on
unlimited the function is not active.
(*) NOTE: The involved contacts are C1 and C2. Only the housings of the lines used must be configured; configure
housings MOD1 and/or MOD2 based on the type of contact an the operating mode to be used. See table.
ContaCt interfaCe of Zone 1 windowS
[Z1] [N1] [MOD1] [Z2] [N2] [MOD2]
(*) (*) 4 (*) (*) (*)
ContaCt interfaCe of Zone 2 and 3 windowS
[Z1] [N1] [MOD1] [Z2] [N2] [MOD2]
(*) (*) 4 (*) (*) (*)
< previous
3 zone villa
t = 5÷∞